44 min listen
Electrical Myth - Wire Length Code - Short #155
Electrical Myth - Wire Length Code - Short #155
ratings:
Length:
12 minutes
Released:
Oct 18, 2022
Format:
Podcast episode
Description
In this short podcast, Bryan covers a common electrical myth about wire length and its relationship with the National Electrical Code. The NEC is concerned with safety—protecting buildings and people—but less so with making sure things work. Wire sizing is a common topic, and length is important because it can contribute to the voltage drop in a circuit. In many cases, we refer to the MCA (minimum circuit ampacity) to select an appropriate wire size. If you run more current through an undersized conductor, it gets hotter and will experience a voltage drop—though not proportionally. It’s worth noting that nothing in the circuit is fixed; voltage, amperage, and resistance all follow Ohm’s law but are variable as different things start happening in a circuit. In many cases, the NEC generally doesn’t require us to size conductors to accommodate for voltage drop. Conductors have some degree of resistance, so longer wires will result in a greater voltage drop than you would see in a shorter wire. It makes sense for the wire to overheat, but that won’t happen because the greater resistance in the circuit will reduce the current. There is less work being done. Longer wires and circuits that are sized correctly shouldn’t overheat or present a safety issue. The NEC recommends but does not require voltage drop to stay below 5% across a conductor. That is a performance recommendation, not a safety concern. We need equipment to perform correctly, but NEC won’t prevent electricians from setting up branch circuits that are longer than the ideal length. Excessively long branch circuits are common in commercial structures, and it’s up to HVAC technicians to notice that and measure the voltage drop to make sure it’s not negatively affecting the equipment. If you have an iPhone, subscribe to the podcast HERE, and if you have an Android phone, subscribe HERE. Check out our handy calculators HERE.
Released:
Oct 18, 2022
Format:
Podcast episode
Titles in the series (100)
Solder Rings, Thermal Imaging and My Grouchy Brother: This episode of HVAC School is a conversation on the merits and faults of embracing new products. We talk about Brazing with Solder Rings, Thermal Imaging, Micron Gauges, Flowing Nitrogen and why you shouldn't hire techs named Todd. by HVAC School - For Techs, By Techs